Anton.

Sprint eVo.

The Sprint eVo Range of intuitive multi-function analysers boasts many improvements over the V2 including enhanced software, improved graphic screen technology and the introduction of the new FreeVo flue probe with its unique moisture extraction system. The Sprint eVo range, with its advanced menu driven software, has a total of 10 separate reports which can be printed on site, including flue gas analysis, differential temperature, let-by/tightness test, working pressure, operating pressure and five separate CO room safety test reports with appliance selection, which will run for the required duration according to BS7967. All printouts have a signature column that can be used either by the customer or the engineer. Printouts also include the serial number and the calibration due date of the instrument used to carry out the test. The Sprint eVo range has many new features to simplify the work of the heating engineer, whom have an ever increasing number of responsibilities, driven by changes in legislation and constant technological improvements. The Anton Sprint eVo rangeā€  is supplied with free of charge software. This enables the engineer to not just print reports on site using our infra-red printer, but to also save their readings to a PDF file on their PC using a USB lead. This can then be used to either printout an A4 report or send via email. In conjunction with your PC calendar software you can also use the PDF to set up a recall/annual service alert. This in turn can be used to ensure your customers are notified when their appliance is due for service and for maintaining appliance history.

Web Links.

Anton flue gas analysers

Kane.

KANE456.

The KANE456 has all key features of the market leading KANE455 along with fixed price servicing and the following new feature:

  • Variable warm which means you’re ready in 90, 60 or 30 seconds.
  • 6 line durable display providing simple & clear information.
  • The unique commissioning test makes the KANE456 truly outstanding – this step by step guide for boiler commissioning lets you print out or wirelessly transfer commission test results.
  • 2 dec point resolution on CO2 for readings between 0-1%.
  • Fast print.
  • Screen protection.
  • All measurement data can be printed quickly & the KANE456 has optional wireless connectivity to iOS & Android devices.

Web Links.

Kane flue gas analysers

TPI.

Model 709R.

The easy to use, TPI 709R combustion efficiency flue gas analyser designed to measure CO, O2, temperature and pressure and calculate CO2 (in a flue), CO/CO2 ratio, efficiency and excess air. All the features you’ll need for boiler commissioning, service and maintenance including performing flow and return and tightness tests. With a large, easy to read, backlit display, simple to navigate operating system at a low starting price and with fixed price annual servicing. The standard kit comes complete with the 709R in a protective rubber boot, temperature sampling probe inc external large water trap and unique in lid water trap (as used by British Gas), soft carry case with shoulder strap, rechargeable battery pack and charger, pressure adaptors, ambient air probe, spare particle filter and instruction manual.

Model 716.

The feature rich, but still easy to use, TPI 716 deluxe combustion efficiency flue gas analyser designed to meet the needs of the busiest gas heating engineer and installer. All the great features of the TPI 709R including the same low cost annual servicing plus the ability to take and record a timed let by / tightness test and timed CO build up test using new menu driven interface which also allows for super quick start up by eliminating the need to perform an initial purge period. It has large capacity pump with visible flow rate on screen and a calibration due countdown amongst many other great features. It also features USB connectivity and PC software as standard and the ability to upgrade now or later to have such features as NO/NOx, High CO, plug in leak sniffer or bluetooth.

Web Links.

TPI flue gas analysers

Service and Calibration.

We provide the service, calibration and repair of measuring instruments to engineers within Gas and Electrical industries. We understand that you rely on measuring equipment and that minimum downtime is essential when instruments are repaired and calibrated. We use an approved Service Centre for Anton and Testo instruments, while Kane and TPI instruments go directly back to the manufacturer. We will arrange the sending of your equipment to the Service Centre and upon receipt, investigation of the instrument will take place and we will submit a quote to you. Assuming the quote has been accepted the instrument will usually be back at our store the following day. In the unlikely event of this quotation not being acceptable the instrument will be returned the following day and only a standard inspection fee will be charged. Most instruments are ready for collection within 3-4 days of being sent. All measurements take place in a temperature and humidity-controlled laboratory, and every measurement made is traceable to UK national standards. The Service Centre is certified through Lloyd Registered Quality Assurance (LRQA) to BS EN ISO9001:2000.